This non-invasive cerebral oximetry system provides real-time, multi-parameter monitoring of regional cerebral oxygen saturation using advanced near-infrared spectroscopy. Designed for continuous monitoring in anesthesia, intensive care, neurology, pediatrics, neurosurgery, cardiovascular surgery, and emergency settings, it offers both wired and wireless sensor options for flexible clinical use. With high accuracy validated in international clinical trials, up to six simultaneous monitoring channels, and parameters covering cerebral oxygenation, tissue oxygenation, pulse oxygenation, and hemoglobin indices, the system delivers a comprehensive and reliable solution for brain oxygen monitoring across diverse patient populations.

Please Log In to access Additional Details and documents …

  • Wireless cerebral oxygen monitoring:
    Only system able to wirelessly monitor brain oxygen saturation, enabling continuous observation during transport and procedures.

  • High-accuracy rSO₂ measurement:
    Clinical trials at Xuanwu and Tiantan hospitals demonstrated <1.5% index error; strong correlation to reference devices for SpO₂, cerebral oxygen, and tissue oxygen.

  • Six-channel multiparameter monitoring:
    Supports rSO₂ (wired + wireless), StO₂, and SpO₂ simultaneously, with additional parameters including CHbO₂, CHb, CtHb, blood oxygen index, AUC, THI, and SQI.

  • Specialized sensor portfolio:
    Adult, pediatric, neonatal, and extra-large rSO₂ sensors; tissue oxygen sensors; wireless headband; pulse oxygen clip.

  • Advanced NIRS technology:
    Uses recognized rSO₂ parameters reflecting cerebral perfusion and brain tissue oxygen status, supporting rapid detection of hypoxia and ischemia.

  • Accurate deep-tissue detection:
    Y-shaped sensor with detection depth of ~2–2.5 cm, unaffected by skin tone, enhancing accuracy across patient groups.

  • Robust hardware performance:
    12" touchscreen, ≥5-hour battery life (15,600 mAh), 1-second data resolution, 32 GB integrated storage with up to 1 year of data, USB/COM/ETH/HUB connectivity, expandable external display.

  • Data review and export:
    Auto/manual waveform review for 5/15/30 minutes or 1/2/6/12/24 hours; full report export available.

  • Wide clinical applications:

    • Anesthesia: real-time cerebral oxygenation during surgery.

    • ICU: detection of perfusion changes, hypoxia, and ischemia.

    • Neurology: evaluation of cerebral oxygenation in stroke stages.

    • Neurosurgery: monitoring during complex procedures and resections.

    • Pediatrics: sensitive monitoring for neonatal/pediatric patients with fragile oxygen balance.

    • Cardiovascular surgery: monitoring during extracorporeal circulation.

    • First aid & emergency: early detection of cerebral hypoxia.

    • Hyperbaric oxygen therapy: compatible with wireless headband for in-chamber use.

  • Regulatory and safety validation:
    CE certification, high-pressure environment testing, and compliance with NIRS clinical monitoring standards.